Zyxel GS1900 switches that had been updated after the first alert could still be compromised: the attackers were exploiting a different vulnerability. The “Patch 3” firmware fixes it.
In the initial alert, CISA and GreyNoise announced that nearly 1,000 Zyxel GS1900 switches had been compromised, and the attack was attributed to the CVE-2026-7273 vulnerability, which Zyxel patched in “Patch 2” firmware. Binarly researchers analyzed the exploit used in the attacks and showed that it was based on another, previously unknown vulnerability: CVE-2026-107441 (score 8.8 according to Zyxel, 9.8 according to Binarly). The check added in Patch 2 was performed too late and did not stop the attack.
The vulnerability is in the switch's web-based administration interface. An attacker who gains access to it—usually from the local network—can execute commands with full privileges, without a password. In the attacks described by GreyNoise, the attackers downloaded a script onto the switches that collected the configuration, administrator passwords (in encrypted form), and network information. More than half of the affected devices still had their factory default passwords.
Zyxel has released the fix as firmware “2.90 Patch 3” for all 10 models in the series (from GS1900-8 to GS1900-48HPv2); the patched version ends in “.3)C0,” for example, 2.90(ABTQ.3)C0 for the GS1900-48HPv2. The advisory does not provide a workaround for those who cannot update and does not specify whether the update removes an attacker who has already gained access.
Why this matters to you: The GS1900 is an inexpensive switch that’s very common in small offices. If your IT provider updated it after the first alert, they may consider the issue resolved, even though the version installed at that time (ending in “.2)C0”) does not provide protection.
What you need to do:
- Ask your IT provider if you have Zyxel GS1900 switches and request that firmware version 2.90 Patch 3 (the version labeled “.3)C0”) be installed, even if you updated after the first alert.
- Ask them to change the switch’s admin password (especially if it was the factory default) and to verify the configuration after the update.
- The switch’s management interface must not be accessible from the guest network or the Internet.